AE-163D Ultra-High Accuracy and High Speed,Key Switch Type Digital Resistance Checker

Optimum for the on a sorting machine, taping machine and painting conveyor for chip. MELF and lead type resistor of B,C,D,F,G,J,K and M class.

  • Ultra-high accuracy and ultra-high stability by the measuring method rejected thermoelectromotiv force.
  • High stability by the improvement of noise immunity for the isolated circuit between analog part and digital part.
  • Available to make the high speed and ultra-high stable measurement by the setting function of average time on measuring value for each range.
  • Range of measurement for absolute value : 0.00mΩ~125.00MΩ
    for % : 5mΩ~109MΩ【±10.000%/-99.99%~+25.00%】
  • Available to select the function for contact check before or after the measurement, or function of non-contact check.
  • RS-232C and Centronics interface are built-in as standard equipment.【GP-IB is option】
  • Transfer function of setting data is built-in as standard equipment.
    (Available to transfer the same setting data to another set of AE-163D)
  • The checking circuit of the abnormal measuring current and voltage is built-in.
Measuring range and Accuracy(at 23℃±5℃)、180days after calibration【1year after calibration : 2times】
Range Measuring Range Test Current Accuracy
SLOW[Hi-Resco.] FAST[LO-Resco.] FAST[Lo-Resco.]
100mΩ 5mΩ~100mΩ 180mA within±0.01%±α±10d within±0.02%±α±2d within±0.03%±2α±3d±[2/(1+n)]d
100.1mΩ~1Ω 180mA within±0.005%±α±3d within±0.02%±α±1d within±0.02%±α±2d±[2/(1+n)]d
10Ω 1.001Ω~10Ω 90mA
100Ω 10.01Ω~100Ω 18mA within±0.005%±1d within±0.02%±1d within±0.02%±2d±[1/(1+n)]d
1kΩ 100.1Ω~1kΩ 9mA
10kΩ 1.001kΩ~10kΩ 0.9mA
100kΩ 10.01kΩ~100kΩ 90μA
1MΩ 100.1kΩ~1MΩ 9μA within±0.007%±1d within±0.05%±2d±[1/(1+n)]d
10MΩ 1.001MΩ~10MΩ 0.9μA within±0.02%±10d within±0.03%±1d within±0.2%±4d±[1/(1+n)]d
100MΩ 10.01MΩ~100MΩ 0.09μA within±0.1%±20d within±0.1%±2d —-
d : digit n : Averaging time(msec.), α=[100/setting value(mΩ)]×0.01% , In case of the measurement of absolute value, add±1digit,
*The above accuracy is under the condition shielded completely. 
Measuring time Remote start Free running
SLOW FAST SLOW FAST
About 24msec.~400msec. About 11msec.~400msec. About 5~2times/sec. About 10~2times/sec.
Test terminal open voltage below 15V
EOC[Endofcomparison]pulsewidth 1~250msec. or continuative
Measuring method 2 or 4 terminal measurement
Comparator set range 4 1/2 digit(20000) both for high and low limit
%range:±9.9.99% / -99.99~+25.00%
Absolute value measurement:00000~12500
Operation condition Temp.:0℃~+50℃、 Humidity:below 80%
Power supply AC85V~265V、50~60Hz、about 50VA
Outer dimension 333(W)×99(H)×300(D)mm
【excluding protruding parts such as rubber legs, etc.】
Weight about 3kg
Option ・GP-IB
・Data cable
・Short termination(Zero ohm standard resistor)

※ We will change the specifications of the catalogue without notice by improvement.

Copyright(c) 2014 AEMIC CORPORATION All Rights Reserved.