<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Aemic Corporation is a manufacturer of Electrical &#38; Test Equipment that specializes in capacitor checker and resistor checker. &#187; Capacitance checker</title>
	<atom:link href="https://ae-mic.com/en/category/products/capacitance-checker/feed/" rel="self" type="application/rss+xml" />
	<link>https://ae-mic.com/en</link>
	<description>Aemic Corporation is a manufacturer of Electrical &#38; Test Equipment that specializes in capacitor checker and resistor checker.</description>
	<lastBuildDate>Thu, 15 Jan 2026 04:35:38 +0000</lastBuildDate>
	<language>ja</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>https://wordpress.org/?v=4.1.41</generator>
	<item>
		<title>AE-3245A 5 Rank sortiing C-tanδChecker</title>
		<link>https://ae-mic.com/en/products/1184/</link>
		<comments>https://ae-mic.com/en/products/1184/#comments</comments>
		<pubDate>Sun, 25 Oct 2015 00:17:15 +0000</pubDate>
		<dc:creator><![CDATA[admin_satoru]]></dc:creator>
				<category><![CDATA[Capacitance checker]]></category>
		<category><![CDATA[Products]]></category>
		<category><![CDATA[Ultrafast capacitance checker]]></category>

		<guid isPermaLink="false">http://ae-mic.com/en/?p=1184</guid>
		<description><![CDATA[Optimum Check in an aging process of electrolytic capac [&#8230;]]]></description>
				<content:encoded><![CDATA[<div class="feature">
<img src="/hp/wp-content/themes/jp/images/AE-3245A.png"></p>
<p class="feature-p">
Optimum Check in an aging process of electrolytic capacitor
</p>
</div>
<div class="explain">
</br></p>
<ul>
<li>Contact-check is equipped as standard function.</li>
<li>Measuring frequency: 120Hz</li>
<li>Measuring time: approx.105msc.[Including contact check &#038; residual voltage check]</li>
<li>Measuring range: 0～39.99mF]/tanδ0～199.9%]</li>
<li>5 Rank sorting.</li>
<li>Centronics interface as standard.</li>
</ul>
</div>
<div>
Measuring range and Accuracy（Ambient temperature 23℃±5℃）
</div>
<div class="spec">
<table>
<tbody>
<tr>
<th class="range">Range</th>
<td>400nF</td>
<td>4μF</td>
<td>40μF</td>
<td>400μF</td>
<td>4mF</td>
<td>40mF</td>
</tr>
<tr>
<th class="range">C Accuracy</th>
<td colspan="4">within ±0.5%±2(digits)</td>
<td>within±2%±2(digits)</td>
<td>within ±2%±5(digits)</td>
</tr>
<tr>
<th class="range">tanδ Accuracy</th>
<td colspan="5"><img src="/en/wp-content/themes/en/images/AE-3245A-01.png"></td>
<td><img src="/en/wp-content/themes/en/images/AE-3245A-02.png"></td>
</tr>
<tr>
<th class="range">Test Mode</th>
<td colspan="6">Serial or Parallel equivalent circuit</td>
</tr>
</tbody>
</table>
</div>
<div>
<div class="setumei2">
In case of tanδ value is 100.0%～199.9%, Accuracy of C and tanδ becomes double.
</div>
</div>
<div class="spec">
<table>
<tr>
<th>Measuring Mode：</th>
<td>Serial Equivalent Circuit</td>
</tr>
<tr>
<th>Measuring Voltage：</th>
<td>Below 400mV (r.m.s.)</td>
</tr>
<tr>
<th>Measuring Method：</th>
<td>5 Terminal Measurement</td>
</tr>
<tr>
<th>Measuring Frequency：</th>
<td>120Hz±0.1%、sine wave</td>
</tr>
<tr>
<th>Measuring Terminal：/th></p>
<td>Front panel: 5-terminal<br />
Rear panel: 8 Pins round type metal consent
</td>
</tr>
<tr>
<th>Contact Check：</th>
<td>Function to output the measurement error when the contact resistance over about 200Ωis detected<br />
at the input terminals more than one.</td>
</tr>
<tr>
<th>Input Protection：</th>
<td>Function to protect the measurement circuit when the voltage on the measurement sample which has<br />
not been discharged is detected being more than about DC2.2V at the continual 4 terminals.<br />
(Residual voltage check)</td>
</tr>
<tr>
<th>Measurement Time：</th>
<td>Remote start Mode: Appr. 105msec.<br />
【Contact check &#038; Residual voltage check】: Appr. 27msec.<br />
【Measurement stabilization time】 : Appr. 45msec.<br />
【Time until the measurement terminal release】Appr. 96msec.<br />
Free running Mode: Appr. 3 cycles/sec.
</td>
</tr>
<tr>
<th>Comparator setting：</th>
<td>Capacity C ： 4 points of LL, L, H and HH : “200 to 3999”<br />
Loss tanδ : “1 to 199.9”
</td>
</tr>
<tr>
<th>Comparator Judgment :
</th>
<td>Digital data comparison method</td>
</tr>
<tr>
<th>Judgment Result Display：</th>
<td>Capacity: CLO, CLG, CGO, CHG, CHI<br />
Tanδ : DGO, DNG<br />
Total : C/D-GO</td>
</tr>
<tr>
<th>Control Signal：</th>
<td>Input: START, HOLD, RESET, CINH, SHIFT, NINH, GINH<br />
Output: GO1. GO2, CNG, DNG, CER, COV, DER, DOV, CEND, MEDD, BUSY, SLCT, CCE, VCE and various type<br />
of shift judgment.</td>
</tr>
<tr>
<th>Data Interface：</th>
<td>Centronics</td>
</tr>
<tr>
<th>Use environment：</th>
<td>Temp.：0℃～+40℃、 Humidity：below 80% or less (no condensation)</td>
</tr>
<tr>
<th>Power supply：</th>
<td>AC85V～265V、50～60Hz、appr. 45VA</td>
</tr>
<tr>
<th>Outer dimension：</th>
<td>432(W)×149(H)×450(D)mm（excluding protruding parts such as rubber legs, etc.）</td>
</tr>
<tr>
<th>Weight：</th>
<td>Appr. 10kg</td>
</tr>
</table>
</div>
<p>※ We will change the specifications of the catalogue without notice by improvement.</p>
]]></content:encoded>
			<wfw:commentRss>https://ae-mic.com/en/products/1184/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>AE-363D Ultra High Speed and High Accuracy, 1kHz Digital Capacitor Checker</title>
		<link>https://ae-mic.com/en/products/65/</link>
		<comments>https://ae-mic.com/en/products/65/#comments</comments>
		<pubDate>Thu, 03 Apr 2014 08:16:53 +0000</pubDate>
		<dc:creator><![CDATA[admin_masahiro]]></dc:creator>
				<category><![CDATA[Capacitance checker]]></category>
		<category><![CDATA[Products]]></category>
		<category><![CDATA[Ultrafast capacitance checker]]></category>
		<category><![CDATA[MLCC検査用]]></category>
		<category><![CDATA[超高速]]></category>

		<guid isPermaLink="false">http://ae-mic.chips.jp/?p=65</guid>
		<description><![CDATA[Optimum for the use on a taping machine for chip and ME [&#8230;]]]></description>
				<content:encoded><![CDATA[<div class="feature">
<img src="/hp/wp-content/themes/jp/images/AE-363D.png"></p>
<p class="feature-p">
Optimum for the use on a taping machine for chip and MELF type capacitor.
</p>
</div>
<div class="explain">
<ul>
<li>Ultra-high speed : 1msec【TYP】</li>
<li>Range of measurement : 20pF～200µF</li>
<li>Measuring frequency : 1kHz±0.1%(Sine wave)</li>
<li>RS-232C and Centronics interface are built-in as standard equipment.【GP-IB is option】</li>
</ul>
</div>
<div>
Measuring range and Accuracy : D＜0.5  (at 23℃±5℃)
</div>
<div class="spec">
<table>
<tbody>
<tr>
<th class="tl-1">Range</th>
<th class="tl-2">Accuracy</th>
<th class="tl-3">Measuring voltage</th>
</tr>
<tr>
<td class="range">20pF</td>
<td>within ±0.2% of rdg±3digit</td>
<td rowspan="6">about 1V</td>
</tr>
<tr>
<td class="range">200pF</td>
<td rowspan="6">within ±0.2% of rdg±2digit</td>
</tr>
<tr>
<td class="range">2nF</td>
</tr>
<tr>
<td class="range">20nF</td>
</tr>
<tr>
<td class="range">200nF</td>
</tr>
<tr>
<td class="range">2μF</td>
</tr>
<tr>
<td class="range">20μF</td>
<td rowspan="2">below 1V</td>
</tr>
<tr>
<td class="range">200μF</td>
<td>within ±0.5% of rdg±3digit[100μF≧]<br />
within(±0.5% of rdg±3digit)×Measuring value/100[100μF＜]
</td>
</tr>
</tbody>
</table>
</div>
<div>
</div>
<div class="spec">
<table>
<tr>
<th>Measuring method :</th>
<td>5-terminal measurement, parallel equivalent circuit</td>
</tr>
<tr>
<th>Measuring frequency :</th>
<td>1kHz±0.1%、Sine wave</td>
</tr>
<tr>
<th>Stray capacity cancel range :</th>
<td>about 20pF</td>
</tr>
<tr>
<th>Full scale and zero temp. coefficient :</th>
<td>within ±100ppm/℃</td>
</tr>
<tr>
<th rowspan="2">Comparator setting range :</th>
<td>【Remote start】1.9msec.～11.5msec.</td>
</tr>
<tr>
<td>【Free running】5～14times/sec.</td>
</tr>
<tr>
<th>Operation condition :</th>
<td>【Temp.】0℃～+50℃、【Humidity】below 85%</td>
</tr>
<tr>
<th>Power supply :</th>
<td>AC85V～265V、50～60Hz、about 60VA</td>
</tr>
<tr>
<th>Outer dimension :</th>
<td>333(W)×99(H)×300(D)mm【excluding protruding parts such as rubber legs, etc.】</td>
</tr>
<tr>
<th>Weight :</th>
<td>about 4kg</td>
</tr>
<tr>
<th>Option :</th>
<td>GP-IB Interface</td>
</tr>
</table>
</div>
]]></content:encoded>
			<wfw:commentRss>https://ae-mic.com/en/products/65/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>AE-365E Ultra high speed &amp; high accuracy 120Hz/1kHz Digital Capacitor Checker</title>
		<link>https://ae-mic.com/en/products/68/</link>
		<comments>https://ae-mic.com/en/products/68/#comments</comments>
		<pubDate>Mon, 03 Mar 2014 08:18:08 +0000</pubDate>
		<dc:creator><![CDATA[admin_masahiro]]></dc:creator>
				<category><![CDATA[Capacitance checker]]></category>
		<category><![CDATA[Products]]></category>
		<category><![CDATA[Ultrafast capacitance checker]]></category>
		<category><![CDATA[大容量MLCC検査用]]></category>
		<category><![CDATA[微小容量]]></category>
		<category><![CDATA[超高速]]></category>

		<guid isPermaLink="false">http://ae-mic.chips.jp/?p=68</guid>
		<description><![CDATA[Optimum model for inspection on taping machine of &#822 [&#8230;]]]></description>
				<content:encoded><![CDATA[<div class="feature">
<img src="/hp/wp-content/themes/jp/images/AE-365E.png"></p>
<p class="feature-p">
Optimum model for inspection on taping machine of &#8220;CHIP&#8221;, &#8220;MELF&#8221;, &#8220;RADIAL&#8221; and &#8220;AXIAL&#8221; Capacitor.
</p>
</div>
<div class="explain">
<ul>
<li>Ultra-high speed : 1msec【TYP】</li>
<li>Range of measurement : 20pF～200µF</li>
<li>Contact checking function as standard</li>
<li>RS-232C and Centronics interface are built-in as standard equipment.【GP-IB is option】</li>
<li>Measuring frequency : 1kHz±0.1%(Sine wave)</li>
</ul>
</div>
<div>
Measurning range and Accuracy（D＜0.1  Ambient temperature 23℃±5℃）
</div>
<div class="spec">
<table>
<tbody>
<tr>
<th class="tl-1">Range</th>
<th class="tl-2">Measuring range</th>
<th class="tl-3">Resolution</th>
<th class="tl-4">Accuracy</th>
<th class="tl-5" colspan="2">Measurement voltage</th>
</tr>
<tr>
<td class="range">2pF</td>
<td>0.000pF～1.999pF</td>
<td>0.001pF</td>
<td>Within ±1.0% of rdg±5digit×α </td>
<td rowspan="8">1kHz,1V±5％ [rms]</td>
<td rowspan="2">1kHz,5V±5V％ [rms]</td>
</tr>
<tr>
<td class="range">20pF</td>
<td>0.00pF～19.99pF</td>
<td>0.01pF</td>
<td>Within ±0.25% of rdg±3digit×α</td>
</tr>
<tr>
<td class="range">200pF</td>
<td>0.0pF～199.9pF</td>
<td>0.1pF</td>
<td>Within ±0.2% of rdg±2digit×α</td>
<td>&#8212;-</td>
</tr>
<tr>
<td class="range">2nF</td>
<td>0.000nF～1.999nF</td>
<td>0.001nF</td>
<td rowspan="4">Within ±0.2% of rdg±2digit</td>
<td>&#8212;-</td>
</tr>
<tr>
<td class="range">20nF</td>
<td>0.00nF～19.99nF</td>
<td>0.01nF</td>
<td>&#8212;-</td>
</tr>
<tr>
<td class="range">200nF</td>
<td>0.0nF～199.9nF</td>
<td>0.1nF</td>
<td>&#8212;-</td>
</tr>
<tr>
<td class="range">2μF</td>
<td>0.000μF～1.999μF</td>
<td>0.001μF</td>
<td rowspan="2">120Hz、0.5V±5％ [rms]</td>
</tr>
<tr>
<td class="range">20μF</td>
<td>0.00μF～19.99μF</td>
<td>0.01μF</td>
<td>Within ±0.3% of rdg±3digit×α</td>
</tr>
<tr>
<td class="range">120μF</td>
<td>0.0μF～119.9μF</td>
<td>0.1μF</td>
<td>Within ±1.0% of rdg±5digit×α</td>
<td>1kHz,1V+5％～-15％ [rms]</td>
<td>&#8212;-</td>
</tr>
<tr>
<td class="range">200μF</td>
<td>0.0μF～199.9μF</td>
<td>0.1μF</td>
<td>Within ±0.5% of rdg±3digit×α</td>
<td>&#8212;-</td>
<td>120Hz、0.5V±5％ [rms]</td>
</tr>
<tr>
<td class="range">1.2mF</td>
<td>0.000mF～1.199mF</td>
<td>0.001mF</td>
<td>Within ±1.5% of rdg±5digit×α</td>
<td>&#8212;-</td>
<td>120Hz、0.5V+5％～5％～-25％ [rms]</td>
</tr>
</tbody>
</table>
</div>
<div>
<div class="setumei2">
※In case of 0.1＜D＜1, 25D/100(%)is added on the above accuracy.　<br />
α：In cae of FAST 2(In case of 2pF Range/1 V α=10)  In case of SLOW 1(In case of 2pF Range/1 V α=5)
</div>
<div class="spec">
<table>
<tr>
<th>Measurement Method</th>
<td>3/5 terminal measurement [Available to select the measuring method on each range]</td>
</tr>
<tr>
<th>Measuring Frequency</th>
<td>120Hz/1kHz±0.1%、sine wave</td>
</tr>
<tr>
<th>Output Impedance</th>
<td>Approx. 1Ω</td>
</tr>
<tr>
<th>Straycapacity revision range</th>
<td>Approx. 30pF</td>
</tr>
<tr>
<th>temperature coefficient</th>
<td>Within ±100ppm/℃[f.s and zero]</td>
</tr>
<tr>
<th rowspan="2">Measurement time</th>
<td>【Free running】FAST：Aprrox.1～5 time/sec.  SLOW：FAST×N(N: The setting number of “average” )</td>
</tr>
<tr>
<td>【Start trigger signal [FAST]】1msec.[Fastest time]</td>
</tr>
<tr>
<th>Comparator set range</th>
<td>Capacitance：1999[120µF/1.2mF range: 1199] with HI and LO limit   tanδ：99.9%</td>
</tr>
<tr>
<th>Use environment</th>
<td>Temperature：0℃～+50℃、　Humidity：Less than 85%</td>
</tr>
<tr>
<th>Power supply</th>
<td>AC85V～265V、50～60Hz、Aprrox. 50VA</td>
</tr>
<tr>
<th>Outer dimension</th>
<td>333(W)×99(H)×300(D)mm</td>
</tr>
<tr>
<th>Weight</th>
<td>Approx. 4kg</td>
</tr>
</table>
</div>
</div>
]]></content:encoded>
			<wfw:commentRss>https://ae-mic.com/en/products/68/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>AE-3122A  High Speed Type・120Hz Digital Capacitor Checker</title>
		<link>https://ae-mic.com/en/products/252/</link>
		<comments>https://ae-mic.com/en/products/252/#comments</comments>
		<pubDate>Fri, 07 Feb 2014 03:35:17 +0000</pubDate>
		<dc:creator><![CDATA[admin_masahiro]]></dc:creator>
				<category><![CDATA[Capacitance checker]]></category>
		<category><![CDATA[Low cost, High accuracy, DC Ohm Meter]]></category>
		<category><![CDATA[Products]]></category>

		<guid isPermaLink="false">http://ae-mic.chips.jp/?p=252</guid>
		<description><![CDATA[Optimum for the use on a taping machine for Aluminum El [&#8230;]]]></description>
				<content:encoded><![CDATA[<div class="feature">
<img src="/hp/wp-content/themes/jp/images/AE-3122A.png"></p>
<p class="feature-p">
Optimum for the use on a taping machine for Aluminum Electrolytic Capacitor and Tantalum Capacitor.
</p>
</div>
<div class="explain">
<ul>
<li>Measuring range：100nF～9.99mF/-79.9%～+99.9%</li>
<li>４-Terminal measurement.</li>
<li>High speed integration method measurement.</li>
<li>Measuring value is displayed in percentage against the reference capacitance value set<br />
Digitally and comparison result by built-in comparator is displayed as –NG,GO,+NG by LED and buzzer.
</li>
<li>BCD parallel out available.</li>
<li>External DC bias possible(max.DC25V)</li>
</ul>
</div>
<div class="spec">
<table>
<tbody>
<tr>
<th class="tl-1">Range No.</th>
<th class="tl-2">Measuring range</th>
<th class="tl-3">Test voltage</th>
<th class="tl-4">Accuracy</th>
</tr>
<tr>
<td class="range">1</td>
<td>100nF～999nF</td>
<td rowspan="5">within 100mV(r.m.s)</td>
<td rowspan="4">within±0.25%±1digit</td>
</tr>
<tr>
<td class="range">2</td>
<td>1μF～9.99μF</td>
</tr>
<tr>
<td class="range">3</td>
<td>10μF～99.9μF</td>
</tr>
<tr>
<td class="range">4</td>
<td>100μF～999μF</td>
</tr>
<tr>
<td class="range">5</td>
<td>1mF～9.99mF</td>
<td>within±0.5%±3digit</td>
</tr>
</tbody>
</table>
</div>
<div>
</div>
<div class="spec">
<table>
<tr>
<th>Measuring method:</th>
<td>4-terminal measuring method、serial equivalent circuit.</td>
</tr>
<tr>
<th>Measuring frequency:</th>
<td>120Hz±0.1%, sine wave form.</td>
</tr>
<tr>
<th rowspan="2">Measuring time:</th>
<td>【in case of remote start mode】about 25msec.</td>
</tr>
<tr>
<td>【in case of free running mode】about 37.5time/sec.</td>
</tr>
<tr>
<th>Display of measured value:</th>
<td>-79.9％～+99.9％</td>
</tr>
<tr>
<th>Comparator setting range:</th>
<td>Upper limit：0.0%～+99.9%,　Lower limit：0.0%～-79.9%</td>
</tr>
<tr>
<th rowspan="4">Input and output signal:</th>
<td>Remote start input：0～+12V or open collector.</td>
</tr>
<tr>
<td>Comparison result output[LO/GO/HI]：open collector [max.80V/100mA]</td>
</tr>
<tr>
<td>End of measurement output[EOC]：open collector [max.80V/100mA]</td>
</tr>
<tr>
<td>BCD parallel output of measuring value：TTL fan out 2</td>
</tr>
<tr>
<th>Operating condition:</th>
<td>Temp.：0℃～+50℃、　Humidity：below 85%</td>
</tr>
<tr>
<th>Power supply:</th>
<td>AC85V～265V、50～60Hz、about 20VA</td>
</tr>
<tr>
<th>Outer dimension:</th>
<td>250(W)×89(H)×250(D)mm（excluding protruding parts such as rubber legs, etc.）</td>
</tr>
<tr>
<th>Weight:</th>
<td>2kg approx.</td>
</tr>
</table>
</div>
<p>※　We will change the specifications of the catalogue without notice by improvement.</p>
]]></content:encoded>
			<wfw:commentRss>https://ae-mic.com/en/products/252/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>AE-369B 120Hz/1kHz High Speed Digital C-tanδ Checker</title>
		<link>https://ae-mic.com/en/products/247/</link>
		<comments>https://ae-mic.com/en/products/247/#comments</comments>
		<pubDate>Fri, 07 Feb 2014 03:30:53 +0000</pubDate>
		<dc:creator><![CDATA[admin_masahiro]]></dc:creator>
				<category><![CDATA[Capacitance checker]]></category>
		<category><![CDATA[Products]]></category>
		<category><![CDATA[Ultrafast capacitance checker]]></category>

		<guid isPermaLink="false">http://ae-mic.chips.jp/?p=247</guid>
		<description><![CDATA[Optimum for the sorting machine of Aluminum and Tantalu [&#8230;]]]></description>
				<content:encoded><![CDATA[<div class="feature">
<img src="/hp/wp-content/themes/jp/images/AE-369B.png"></p>
<p class="feature-p">
Optimum for the sorting machine of Aluminum and Tantalum Electrolytic Capacitor.</p>
</div>
<div class="explain">
<ul>
<li>Measuring frequency  120Hz/1kHz[Sine wave]</li>
<li>Measuring speed  8.2msec.(1kHz)/12.5msec.(120Hz)</li>
<li>Measuring range   　 C：0～39.99mF/tanδ：0～199.9%</li>
<li>Test mode          Serial or Parallel equivalent circuit.</li>
<li>Comparison output by the built-in comparator.</li>
<li>Data interface       Either GP-IB、RS-232C or Centronics.【Option】</li>
</ul>
</div>
<div>
Measuring range and Accuracy（Ambient temperature 23℃±5℃）
</div>
<div class="spec">
<table>
<tbody>
<tr>
<th class="range" rowspan="2">Range</th>
<td>1kHz</td>
<td>40nF</td>
<td>400nF</td>
<td>4μF</td>
<td>40μF</td>
<td>400μF</td>
<td>4mF</td>
</tr>
<tr>
<td>120Hz</td>
<td>400nF</td>
<td>4μF</td>
<td>40μF</td>
<td>400μF</td>
<td>4mF</td>
<td>40mF</td>
</tr>
<tr>
<th class="range">C Accuracy</th>
<td colspan="5">±0.3％±2(digit)</td>
<td>±y％±2(digit)</td>
<td>±1％±5(digit)</td>
</tr>
<tr>
<th class="range">tanδ Accuracy</th>
<td colspan="6"><img src="/hp/wp-content/themes/jp/images/AE-369B-01.png"></td>
<td><img src="/hp/wp-content/themes/jp/images/AE-369B-02.png"></td>
</tr>
<tr>
<th class="range">Test Mode</th>
<td colspan="7">Serial or Parallel equivalent circuit</td>
</tr>
</tbody>
</table>
</div>
<div>
<div class="setumei2">
β：5(120Hz) / 10(1kHz)<br />
γ：1(120Hz) / 0.5(1kHz)<br />
In case of tanδ value is 100.0%～199.9%, Accuracy of C and tanδ becomes double.
</div>
</div>
<div class="spec">
<table>
<tr>
<th>Measuring Method</th>
<td>5 Terminal Measurement</td>
</tr>
<tr>
<th>Measurement Voltage</th>
<td>Below 400mV (r.m.s.)</td>
</tr>
<tr>
<th>Measuring Frequency</th>
<td>120Hz/1kHz±0.1%、sine wave</td>
</tr>
<tr>
<th rowspan="2">Measurement Time</th>
<td>【Remote start】about 8.2msec.(1kHz) /  about 12.5msec.(120Hz)</td>
</tr>
<tr>
<td>【Free running】about 3 time/sec.</td>
</tr>
<tr>
<th>DCDC Bias</th>
<td>DC1.5V（built-in）and DC 0～25V(remote)</td>
</tr>
<tr>
<th>Use environment</th>
<td>Temp.：0℃～+50℃、　Humidity：below 80%</td>
</tr>
<tr>
<th>Power supply</th>
<td>AC85V～265V、50～60Hz、about 30VA</td>
</tr>
<tr>
<th>Outer dimension</th>
<td>333(W)×99(H)×300(D)mm（excluding protruding parts such as rubber legs, etc.）</td>
</tr>
<tr>
<th>Weight</th>
<td>Approx. 3.8kg</td>
</tr>
</table>
</div>
<div class="spec">
<table class="spec-option">
<tr>
<th>GP-IB</th>
<td rowspan="3">Only one kind of interface can be provided with the checker</td>
</tr>
<tr>
<th>RS-232C</th>
</tr>
<tr>
<th>Centronics Interface</th>
</tr>
</table>
</div>
<p>※　We will change the specifications of the catalogue without notice by improvement.</p>
]]></content:encoded>
			<wfw:commentRss>https://ae-mic.com/en/products/247/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>AE-323A  High Speed Type・1kHz Digital Capacitor Checker</title>
		<link>https://ae-mic.com/en/products/254/</link>
		<comments>https://ae-mic.com/en/products/254/#comments</comments>
		<pubDate>Tue, 07 Jan 2014 03:35:40 +0000</pubDate>
		<dc:creator><![CDATA[admin_masahiro]]></dc:creator>
				<category><![CDATA[Capacitance checker]]></category>
		<category><![CDATA[Low cost, High accuracy, DC Ohm Meter]]></category>
		<category><![CDATA[Products]]></category>

		<guid isPermaLink="false">http://ae-mic.chips.jp/?p=254</guid>
		<description><![CDATA[Optimum for the use on a taping machine for Film Capaci [&#8230;]]]></description>
				<content:encoded><![CDATA[<div class="feature">
<img src="/hp/wp-content/themes/jp/images/AE-323A.png"></p>
<p class="feature-p">
Optimum for the use on a taping machine for Film Capacitor and Ceramic Capacitor.
</p>
</div>
<div class="explain">
<ul>
<li>Measuring range：10pF～9.99μF/±99.9%</li>
<li>5-Terminal measurement.</li>
<li>High speed integration method measurement.</li>
<li>Measuring value is displayed in percentage against the reference capacitance value set<br />
Digitally and comparison result by built-in comparator is displayed as –NG,GO,+NG by LED and buzzer.
</li>
<li>BCD parallel out available.</li>
<li>External DC bias possible(max.DC25V)</li>
</ul>
</div>
<div class="spec">
<table>
<tbody>
<tr>
<th class="tl-1">Range No.</th>
<th class="tl-2">Measuring range</th>
<th class="tl-3">Test voltage</th>
<th class="tl-4">Accuracy</th>
</tr>
<tr>
<td class="range">0</td>
<td>10pF～99.9pF</td>
<td rowspan="6">1V(r.m.s)approx.</td>
<td rowspan="6">within±0.25%±0.25p±1digit</td>
</tr>
<tr>
<td class="range">1</td>
<td>100pF～999pF</td>
</tr>
<tr>
<td class="range">2</td>
<td>1nF～9.99nF</td>
</tr>
<tr>
<td class="range">3</td>
<td>10nF～99.9nF</td>
</tr>
<tr>
<td class="range">4</td>
<td>100nF～999nF</td>
</tr>
<tr>
<td class="range">5</td>
<td>1μF～9.99μF</td>
</tr>
</tbody>
</table>
</div>
<div>
</div>
<div class="spec">
<table>
<tr>
<th>Measuring method:</th>
<td>5-terminal measuring method、parallel equivalent circuit.</td>
</tr>
<tr>
<th>Measuring frequency:</th>
<td>1kHz±0.1%, sine wave form.</td>
</tr>
<tr>
<th>Stray capacitance cancel range:</th>
<td>10pF approx.</td>
</tr>
<tr>
<th rowspan="2">Measuring time:</th>
<td>【in case of remote start mode】about 3.2msec.</td>
</tr>
<tr>
<td>【in case of free running mode】about 68time/sec.</td>
</tr>
<tr>
<th>Comparator setting range:</th>
<td>Upper limit：0.0%～+99.9%,　Lower limit：0.0%～-99.9%<br />
</tr>
<tr>
<th>Display of comparison result by comparator:</th>
<td>LED display of -NG/GO/+NG, and buzzer.</td>
</tr>
<tr>
<th>Comparator setting range:</th>
<td>Upper limit : 0.0% ～ +99.9%, Lower limit : 0.0% ～ -99.9%</td>
</tr>
<tr>
<th>Display of comparison result by comparator:</th>
<td>LED display of -NG/GO/+NG,and buzzer.</td>
</tr>
<tr>
<th rowspan="4">Input and output signal:</th>
<td>Remote start input：0～+12V or open collector.</td>
</tr>
<tr>
<td>Remote start input：0～+12V or open collector.</td>
</tr>
<tr>
<td>End of measurement output[EOC]：open collector [max.80V/100mA]</td>
</tr>
<tr>
<td>BCD parallel output of measuring value：TTL fan out 2</td>
</tr>
<tr>
<th>Operating condition:</th>
<td>Temp.：0℃～+50℃、　Humidity：below 85%</td>
</tr>
<tr>
<th>Power supply:</th>
<td>AC85V～265V、50～60Hz、about 15VA</td>
</tr>
<tr>
<th>Outer dimension:</th>
<td>250(W)×89(H)×250(D)mm（excluding protruding parts such as rubber legs, etc.）</td>
</tr>
<tr>
<th>Weight:</th>
<td>2kg approx.</td>
</tr>
</table>
</div>
<p>※　We will change the specifications of the catalogue without notice by improvement.</p>